![]() | MAWS301 Automatic Weather Station |
The new Vaisala MAWS301 Automatic Weather Station is designed especially for applications where commercial power or communication networks do not exist or are not economical enough. It is based on the latest measurement and communication technology. The MAWS301 interfaces with various telecommunication equipment such as PSTN, GSM and radio modems, as well as satellite transmitters. Embedded with sophisticated, yet easy-to-use technology, the MAWS301 is the ideal choice for a wide range of applications where reliable and accurate meteorological mesurements are required at a low cost-of-ownership.
QML102 AWS Logger
Processor: 32-bit Motorola
A/D conversion:16 bit
Data logging memory
Internal: 1.7 Mbytes internal Flash memory
Optional: Up to 160 Mbytes on Compact Flash memory card
Sensor inputs
Analog: 10 Analog inputs (20 single ended inputs)
Frequency: 2 Counter/frequency inputs, Internal channel for PMT16A pressure transducer
Accuracies over the operating temperature range (-35 °C - +50 °C)
Temperature (Pt-100) measurements
Typical accuracy accross measured temperature:
range -50 °C - +80 °C Better than ± 0.06 °C
Maximum error across measured temperature:
range -35 °C - +50 °C Less than ± 0.12 °C
Maximum error at 0 °C Less than ± 0.06 °C
Voltage measurement
±2.5 V range: Better than 0.08% F.S. ±150 µV
±250 mV range: Better than 0.18% F.S. ±15 µV
±25 mV range: Better than 0.18% F.S. ±3 µV
±6.5 mV range: Better than 0.18% F.S. ±3 µV
Frequency measurements: 0.003 % + resolution 241 nsec. (up to 2 kHz)
Common mode range: +5 V / -4 V
Real-time-clock
Standard: Better than 20 sec/month
With GPS option: Configurable, default 5 sec/month
Serial communication
Standard: One RS-232
Optional: Two (2) optional plug-in slots for communication modules for increasing the number of serial I/O channels up to 5 pcs
Speed: 300 ... 19, 200 bps
Parameters: Configurable speed, start bits, data bits, stop bits, parity, XON/XOFF and check sum
External powering
Voltage: 8 ... 14 VDC recommended (30 V max.)
Optional internal battery: 1.3 Ah/6 V
Power consumption: < 10 mA/6 V (typically with basic 5 sensors)
Solar panel/batteries
Panel options: 12 W/12 V and 24 W/12 V
Back-up battery options: 6, 12 or 24 Ah rechargeable, sealed lead acid, maintenance free
Mains power
Optional module BWT15SX-Assy,: 85 … 264 VAC
Environmental
Temperature: Operating –35 ... +55 °C, Storage –50 ... +70 °C
Humidity: 0 ... 100 % RH
Emissions: CISPR 22 class B (EN55022)
Immunity
ESD immunity: IEC 61000-4-2
RF field immunity: IEC 61000-4-3
EFT immunity: IEC 61000-4-4
Surge (lightning pulse): IEC 61000-4-5
Conducted RF immunity: IEC 61000-4-6
Sensors
Wind: WMS302, WAA/WAV151, WAS425A
Pressure: PMT16A
Temperature, Relative Humidity: QMH102
Solar Radiation: QMS101, QMS102, CM6B, CM11, QMN101
Sunshine Duration: DSU12
Precipitation: QMR102, DRD11A (Detection)
Soil/Water Temperature: QMT103, QMT107
Soil Moisture: ML2x
Snow Height: DCU7210
Leaf Wetness: QLW101
Water Level: QMV101, QMV102, DCU7110
Water Quality: MiniSonde4A
Optical Sensors
Cloud Height: CT25K
Visibility: FD12
Present Weather: FD12P, PWD11
| DATASHEET | » |
| HANDBOOK | » |






Share